In the context of the Berlin SPARQL Benchmark, I have repeatedly written about measurement procedures and steady state. The point is that the numbers at larger scales are unreliable due to cache behavior if one is not careful about measurement and does not have adequate warmup. Thus it came to pass that one cut of the BSBM paper had 3 seconds for MySQL and 100 for Virtuoso, basically through ignoring cache effects.
So we decided to do it ourselves.
The score is (updated with revised innodb_buffer_pool_size
setting, based on advice noted down below):
n-clients |
Virtuoso |
MySQL (with increased buffer pool size) |
MySQL (with default buffer poll size) |
1 |
41,161.33 |
27,023.11 |
12,171.41 |
4 |
127,918.30 |
(pending) |
37,566.82 |
8 |
218,162.29 |
105,524.23 |
51,104.39 |
16 |
214,763.58 |
98,852.42 |
47,589.18 |
The metric is the query mixes per hour from the BSBM test driver output. For the interested, the complete output is here.
The benchmark is pure SQL, nothing to do with SPARQL or RDF.
The hardware is 2 x Xeon 5345 (2 x quad core, 2.33 GHz), 16 G RAM. The OS is 64-bit Debian Linux.
The benchmark was run at a scale of 200,000. Each run had 2000 warm-up query mixes and 500 measured query mixes, which gives steady state, eliminating any effects of OS disk cache and the like. Both databases were configured to use 8G for disk cache. The test effectively runs from memory. We ran an analyze table on each MySQL table but noticed that this had no effect. Virtuoso does the stats sampling on the go; possibly MySQL also since the explicit stats did not make any difference. The MySQL tables were served by the InnoDB engine. MySQL appears to cache results of queries in some cases. This was not apparent in the tests.
The versions are 5.09 for Virtuoso and 5.1.29 for MySQL. You can download and examine --
MySQL ought to do better. We suspect that here, just as in the TPC-D experiment we made way back, the query plans are not quite right. Also we rarely saw over 300% CPU utilization for MySQL. It is possible there is a config parameter that affects this. The public is invited to tell us about such.
Update:
Andreas Schultz of the BSBM team advised us to increase the innodb_buffer_pool_size
setting in the MySQL config. We did and it produced some improvement. Indeed, this is more like it, as we now see CPU utilization around 700% instead of the 300% in the previously published run, which rendered it suspect. Also, our experiments with TPC-D led us to expect better. We ran these things a few times so as to have warm cache.
On the first run, we noticed that the Innodb warm up time was somewhere well in excess of 2000 query mixes. Another time, we should make a graph of throughput as a function of time for both MySQL and Virtuoso. We recently made a greedy prefetch hack that should give us some mileage there. For the next BSBM, all we can advise is to run larger scale system for half an hour first and then measure and then measure again. If the second measurement is the same as the first then it is good.
As always, since MySQL is not our specialty, we confidently invite the public to tell us how to make it run faster. So, unless something more turns up, our next trial is a revisit of TPC-H.